<<--- See More Of "Country Club Equipment"
| Name | REFRIGERATOR |
| Tag | U-LINE |
| Location | TENNIS CLUBHOUSE |
| Hazmat | Duty engineer |
| Part | 75RWH-00 |
| Serial | 003114-12-00101 |
| ServiceDate | 2004-11-29 |
| Service Interval | 0 |
| Service Warn | 0 |
| Date Last Serviced | 2004-09-06 |
| Serviced By | Jose |
| Tools | refrigeration manifolds and wrenches, multimeter, screwdrivers, coil cleaner, wire brushes, air compressor |
| Date Installed | |
| Lead Time for Parts | 0 |
| Agreement | verbal |
| Manual Location | none |
| Locked | Unplug form the wall's outlet. |
| Work Instructions 1 | Notify tennis pro. |
| Work Instructions 2 |
Quarterly service:
-check temperature -check thermostat -clean evaporator and condensor, first with coil cleaner and wire brush then use air gun to blow away dirt and lint -check refrigerant pressure -visually inspect compressor -check amperage In case of major problem consult PELCO |
|